Please Wait...

Skill Assessment Template -Form Fill

Facility Identification
Q01

District name

Q02

District code

Q03

District Type

Q04

Block name

Q05

Block code

Q06

Facility Name

Q07

Interview Details

Q07_1

Facility Observation Date

Q07_2

Interviewer Name

Q07_3

Interviewer Code

Q07_4

Result of interview

Questions
A01

Name of the person interviewed

A02

Position of person interviewed?

A03

Do you know how to do an Interval IUCD insertion?

A04

Are you willing to demonstrate the skill

A05

Please ensure that the following items are available before starting the skill demonstration

A05_1

Zoe model

A05_2

Cu IUCD 380 A (expiry date checked)

A05_3

Or multi load 375 (expiry date checked)

A05_4

Light source

A05_5

Sim’s/Cusco’s vaginal Speculum

A05_6

Sponge holding forceps

A05_7

Cheatle’s forceps

A05_8

Anterior vaginal wall retractor (if Sim’s speculum used)

A05_9

Volsellum forceps curved / tenaculum

A05_10

Uterine sound

A05_11

Pair of scissors

A05_12

Povidone iodine or chlorhexidine

A05_13

Gloves

A05_14

0.5 % chlorine solution

A05_15

Tray for keeping instruments

A05_16

Cotton swabs

A06

Did the nurse review the client’s medical history?

A07

Did the nurse review the client’s reproductive history?

A08

Did the nurse instruct the client to empty her bladder?

A09

Did the nurse instruct the client to wash the perineal area?

A10

Did the nurse inform the client about the IUCD procedure?

A11

Did the nurse wash hands?

A12

Did the nurse dry her hands?

A13

Did the nurse palpates the abdomen?

A14

Did the nurse wash hands?

A15

Did the nurse dry her hands?

A16

Did the nurse wear sterile gloves?

A17

Did the nurse wear gloves in both hands?

A18

Did the nurse inspects the external genitalia?

A19

Do you find any potential problems in the examination?

A20

Did the nurse perform the Speculum exam?

A21

Did the nurse perform the bimanual exam?

A22

What examination was done first - Speculum or bimanual?

A23

Did the nurse remind the client to let know if she feels pain?

A24

Did the nurse insert the speculum to visualize the cervix

A25

Did the nurse cleanses the cervical os with antiseptic?

A26

Did the nurse cleanses the vagina wall with antiseptic?

A27

Did the nurse gently grasp the cervix with tenaculum / Volsellum?

A28

Did the nurse apply gentle traction

A29

Did the nurse insert the sound using the “no touch technique”?

A30

Is the IUCD is Cu IUCD 380 A

A31

Did the health care provider open a sterile package of IUCD, from bottom by pulling back plastic cover approximately 1/3 upwards

A32

Did the health care provider hold the IUCD package, stabilize the IUCD and remove plunger rod, inserter tube and card from the package

A33

Did the nurse grasp the IUCD with a Kelly’s l forceps using the no touch technique?

A34

Can you tell me how far you should insert the Kelly’s forceps?

A35

Did the health care provider set the blue depth gauge to the measurement of the uterus

A36

Did the health care provider insert the loaded IUCD and release it into the uterus using withdrawl technique

A37

Did the health care provider remove the plunger rod

A38

Did the health care provider push the insertion tube upwards till a slight resistance is felt?

A39

Is the IUCD is Cu IUCD 375

A40

Did the health care provider grasp the insertion tube and the IUCD string together at the lower end of the tube

A41

Did the health care provider move the cervical guard to the measurement of the uterus

A42

Did the health care provider gently advance the loaded IUCD into the uterine cavity until the cervical guard touches the cervix or a slight resistance is felt

A43

Did the health care provider continue to apply gentle downward traction to the tenaculum/volsellum while removing the inserter tube from the cervical canal

A44

Did the health care provider withdraw the insertion tube until the IUCD strings can be seen?

A45

Did the nurse remove the sponge holding forceps from the cervix?

A46

Did the nurse remove the speculum from the cervix?

A47

Did the nurse place a hand on the lower part of the uterus with the finger towards the fundus?

A48

Did the nurse push the uterus upward?

A49

Did the nurse push the uterus backward?

A50

Did the nurse release the IUCD at the fundus?

A51

Did the nurse continue to stabilize the uterus with a hand on the abdomen?

A52

Did the nurse sweep the Kelly’s forceps to the side wall of the uterus?

A53

Did the nurse keep Kelly’s forceps slightly open while removing?

A54

Did the nurse stabilize the uterus until Kelly’s forceps were completely out of the uterus?

A55

Did the nurse use a sharp Mayo scissors to cut the IUCD strings to 3-4 cms

A56

Did the nurse examine the cervix?

A57

Can you tell me what will you do if the strings are visible and protruding from the cervix?

A58

Did the nurse remove all the instruments?

A59

Did the nurse place all the instruments in 0.5% chlorine solutions for 10 minutes?

A60

Did the nurse discard all other waste materials (IUCD wrapper, gloves) as per IP protocol?

A61

Did Nurse wash both gloved hands in .5% chlorine solution?

A62

Did the nurse tell the mother about the successful insertion of the IUCD?

A63

Did nurse provide post insertion instructions for follow up?